Contentful ID
4237666130
Oak Ridge National Laboratory (ORNL)
Contentful ID
51f49ecf-01c1-c1ac-95c0-9e565043d6b4-draft
Company Values
Entity Description
A federally-funded science and technology research laboratory operated by UT-Battelle for the United States Department of Energy
Entity Name
Oak Ridge National Laboratory (ORNL)
Focus Areas
General - Organization
Entity Type
National Lab
Is LCRI Company?
No
Technology Areas
Technology Description
SmAHTR is a fluoride salt-cooled, graphite moderated molten salt reactor that utilizes solid, static, LEU-based TRISO fuel with a capacity of 125 MWt/50MWe. All primary components are integrated into a single vessel. A design variant for hydrogen production applications, the SmAHTR-CTC (carbonate thermochemical cycle), is also under development.
Technology Name
Small, Modular Advanced High-Temperature Reactor (SmAHTR)
Kairos Power
Contentful ID
ae92b163-fbc1-b62e-cdb9-887bec3b9ed1-draft
Company Values
Entity Description
A nuclear engineering and technology startup company focused on the commercialization of the fluoride salt-cooled high-temperature reactor
Entity Name
Kairos Power
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
The FHR is a fluoride-based salts-cooled, high-temperature thermal spectrum reactor with solid, pebble-type TRISO uranium fuel. Its "Nuclear Air Combined Cycle" system enables highly responsive electricity generation through co-firing with natural gas or hydrogen.
Technology Name
Fluoride Salt-Cooled High-Temperature Reactor (FHR)
Japan Atomic Energy Agency (JAEA)
Contentful ID
1d678c9d-a0d1-2a2d-c26c-da81e323604c-draft
Company Values
Entity Description
A Japanese Administrative Institution and Japan's comprehensive nuclear energy research and development institute
Entity Name
Japan Atomic Energy Agency (JAEA)
Focus Areas
General - Organization
Entity Type
Other
Is LCRI Company?
No
Technology Areas
Technology Description
GTHTR300 is a helium-cooled, graphite-moderated thermal spectrum, prismatic high-temperature gas-cooled reactor with 14% enriched uranium-based TRISO fuel with flexible industrial/electricity generation applications. It provides a maximum of 600 MWt power and 100-300 MWe, depending on its application.
Technology Name
Gas Turbine High Temperature Reactor, 300 MW (GTHTR300)
French Alternative Energies and Atomic Energy Commission (CEA)
Contentful ID
1610bac6-78e1-41a5-b25c-299c7e0ffd39-draft
Company Values
Entity Description
A French public, government-funded research organization that conducts research and development in the areas of defense and security, low-carbon energies, industrial technologies, and the physical and life sciences
Entity Name
French Alternative Energies and Atomic Energy Commission (CEA)
Focus Areas
General - Organization
Entity Type
Other
Group/Division/Lab name
Nuclear Energy
Is LCRI Company?
No
Technology Areas
Technology Description
ASTRID is a sodium-cooled, pool-type fast spectrum reactor fueled by mixed oxide (MOX) fuel with a capacity of 1500 MWt/600 MWe. As an industrial demonstration reactor, ASTRID will be used to optimize the design of future commercial reactors under the umbrella of the Generation IV forum (GIF).
Technology Name
Advanced Sodium Technological Reactor for Industrial Demonstration (ASTRID)
Argonne National Laboratory
Contentful ID
179502e2-be96-67f9-0cd6-b5bbc6ae887d-draft
Company Values
Entity Description
A science and engineering research laboratory operated by the University of Chicago Argonne LLC for the US Department of Energy
Entity Name
Argonne National Laboratory
Focus Areas
General - Organization
Entity Type
National Lab
Group/Division/Lab name
Nuclear Engineering Division
Is LCRI Company?
No
Technology Areas
Technology Description
As part of the Heavy Liquid Metal Coolant (HLMC) research initiative, Argonne National Laboratory (ANL) has developed multiple multiple advanced reactor technologies, including the Secure Transportable Autonomous Reactor with Liquid Metal (STAR-LM) and the Small Secure Transportable Autonomous Reactor (SSTAR). SUPERSTAR, a lead-cooled, pool-type fast spectrum reactor is the most recent HLMC research initiative design. It has a capacity of 300 MWt/120 MWe is designed for electricity generation on the export market.
Technology Name
Sustainable Proliferation-resistance Enhanced Refined Secure Transportable Autonomous Reactor (SUPERSTAR)
Atomic Energy of Canada Ltd (AECL)
Contentful ID
069910a9-efe5-f9f9-0fa1-b1ac4b60691c-draft
Company Values
Entity Description
AECL is a Canadian federal crown corporation and Canada's largest nuclear science and technology laboratory, well known for developing the CANDU reactor technology.
Entity Name
Atomic Energy of Canada Ltd (AECL)
Focus Areas
General - Organization
Entity Type
Other
Is LCRI Company?
No
Technology Description
Fueled by plutonium and thorium, this pressure tube-type SCWR operates in the thermal neutron spectrum at a high pressure of 25 MPa. It is moderated by heavy water and cooled by supercritical light water, utilizes a direct steam cycle power conversion system, and has a capacity of 2540 MWt/1200 MWe. AECL is also developing a small, modular version of its SCWR called the Supersafe Reactor (SSR).
Technology Name
Candian Supercritical Water Reactor (Canadian SCWR)
Moltex Energy, LLP
Contentful ID
d20ffc5b-9b84-5717-d550-e7734ec00dde-draft
Company Values
Entity Description
A UK-based company focused on the development and commercialization of their modular Stable Salt Reactor, a molten salt reactor variant with liquid fuel contained in conventional, static fuel assemblies
Entity Name
Moltex Energy, LLP
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
The SSR is a zirconium and sodium fluoride salts-cooled, graphite-moderated thermal spectrum molten salt reactor. 8 37.5 MWe modules form a standard 750 MWt/300MWe unit. The static form of the liquid fuel salt eliminates many of the technical hurdles associated with mobile, liquid fuels typical to molten salt reactors; fuel assemblies are designed for compatibility with existing IAEA Safeguard procedures
Technology Name
Stable Salt Reactor (SSR)
Oklo (formerly UPower)
Contentful ID
2653aaf0-76da-24b3-319d-2f248f815d4f-draft
Company Values
Entity Description
Y Combinator-hosted Oklo is a nuclear energy startup company founded by graduates of MIT's Nuclear Engineering department to develop and commercialize a container-sized MW-scale "nuclear generator"
Entity Name
Oklo (formerly UPower)
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
Oklo's reactor is a liquid metal-cooled, fast spectrum reactor utilizing a metallic fuel. It is designed to be small, portable, and suitable for remote deployment.
Ultra Safe Nuclear Corporation
Contentful ID
eba05547-fd6b-fb6b-4008-6489368a9c7a-draft
Company Values
Entity Description
a developer of innovative nuclear technologies, including TRISO-based fuels for conventional reactors, "micro-modular" advanced reactors and nuclear thermal propulsion systems
Entity Name
Ultra Safe Nuclear Corporation
Focus Areas
General - Organization
Entity Type
Company
Is LCRI Company?
No
Technology Areas
Technology Description
The MMR is a 5 or 10 MWe gas-cooled, graphite-moderated thermal spectrum advanced reactor. It is fueled by Ultra Safe Nuclear Corp.'s own Fully Ceramic Microencapsulated (FCM), TRISO-based fuel and is designed for 20+ years without refueling. In this design, power production, power conversion and electricity generation are integrated into a single factory-fabricated vessel. A service agreement is under development as part of the Canadian Nuclear Safety Commission's Pre-Licensing Vendor Design Review process.
Technology Name
Micro Modular Reactor (MMR)
Atomic Energy of Canada (AECL)
Contentful ID
a99a60c3-10d1-ac11-4fa1-68dd391392b3-draft
Company Values
Entity Description
Federal Crown corporation responsible for managing Canada's radioactive waste liabilities and enabling nuclear science and technology.
Entity Name
Atomic Energy of Canada (AECL)
Entity Owler ID
221122
Focus Areas
General - Organization
Entity Type
National Lab
Is LCRI Company?
No
Technology Description
The Canadian SCWR is a pressure tube-type supercritical water-cooled, heavy water-moderated thermal spectrum reactor with an output of 2540 MWt/1200 MWe.
Technology Name
Canadian Supercritical Water-Cooled Reactor (Canadian SCWR)